- Standard Model(S) : Inside S.S. 304 & outside mild steel powder coated
- GMP Model(G) : Inside S.S. 304 & outside S.S. 304
- Temperature Range : 20°C to 60°C
- Temperature Accuracy : ± 0.2°C
- Temp Uniformity : ± 2°C
- Humidity Range : 40% to 95% RH
- Humidity Accuracy : ± 2% RH
- Humidity Uniformity : ± 3% RH

Stability chamber
Climogen Scientific chambers are perfectly designed for the high requirements of stability studies and climatic tests. With Stability Chambers specifically developed to meet FDA/ICH stability requirements generating exceptional control and uniformity of both temperature and humidity.
Climogen Scientific chambers feature various safety feature, audio visual alarms, 21 CFR part 11 software and a vast range of options and is the most preferred choice for stability studies. Every Thermolab Scientific Chamber repeatedly produces required conditions, structural integrity that keeps the chamber working properly through years of demanding test cycles and measuring equipment’s that precisely records all test data.
Featured
Software featured

Mobile alert system

Touch screen display

Safety alarm system

Documentation

Standby refrigeration system

Software

Standby humidity system
Stability chambers are specialized units used to store products under controlled temperature and humidity conditions, typically ranging from 2°C to 40°C and 20% to 95% relative humidity. They feature precise temperature and humidity control, uniform distribution of conditions, and programmable controllers for easy monitoring.
- 21 CFR Part 11 Compliance Window based communication software for data management
- Stand by refrigeration system & Stand by humidity system (Except for 90 Ltrs.)
- Scanner 4 point temperature and 4 point humidity scanner complete with sensors and printer interface and data storage facility.
- Mobile Alert system
- Door Access Security System
- Security Alarm System
Model | Internal | Dimensions in cms | Max No. of Trays | |||||
---|---|---|---|---|---|---|---|---|
(s)OR(G) | Cu.Ft/Ltrs. | Internal | External | |||||
W | D | H | W | D | H | |||
TH 90 S/G | 3/900 | 45 | 40 | 50 | 60 | 82 | 104 | 3 |
TH 200/G | 8/200 | 60 | 63 | 60 | 75 | 106.5 | 117 | 4 |
TH 325/G | 12/325 | 60 | 60 | 90 | 75 | 106.5 | 147 | 6 |
TH 400 S/G | 16/400 | 60 | 63 | 106 | 75 | 106.5 | 163 | 7 |
TH 600 S/G | 22/600 | 80 | 80 | 95 | 95 | 126.5 | 154 | 6 |
TH 800 S/G | 28/800 | 80 | 80 | 125 | 95 | 126.5 | 187 | 9 |
TH 1000 S/G | 32/1000 | 80 | 8 | 157 | 95 | 126.5 | 219 | 11 |